Water shortage fault, after 4 minutes water inputting continuously, water is still not full, Water shortage icon lights up and Fault icon flashes. 44-330-175-5511 [Wash]short press: control the on and off of the blue light, long press for S seconds: the program is forced to enter the cleaning process control.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'manuals_plus-narrow-sky-2','ezslot_17',709,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-narrow-sky-2-0');[Thick]During ice making process (the ice-making lamp is always on), press this button, and the screen will immediately display a twodigit number,Press this button again, and the number will increase by +1, and the ice-making time will be extended by one minute accordingly.During ice making process (the ice-making lamp is always on), press this button, and the screen will immediately display a twodigit number.Press this button again, and the number will decrease by -1, And the ice-making time will be shortened by one minute accordingly.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'manuals_plus-netboard-2','ezslot_19',710,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-netboard-2-0');Ice Thickness Parameters-The ice thickness of the ice maker will vary during ice making in different ambient temperatures or different seasons, so users are required to adjust the ice thickness parameters. The serious scale in the tank will jam the impeller of the pump and cause the water inside the machine to be unable to circulate. This item: VEVOR Commercial Ice Maker Machine, WiFi Control 177LBS/24H 121LBS Large Storage Ice Machine with Upgraded LCD Panel, SECOP Compressor, Air-Cooled, Include 2 Water Filters, Water Drain Pump, 2 Scoops $1,699.99 Ice Bags with Drawstring Heavy Duty Commercial Grade (10 lb Pack 500) $73.99 ($0.15/Count) The power connection should be applied to the nameplate, the specified power supply should be used, and the specifications of the wires used to connect the circuit should be determined to meet the requirements. If the soft wire of the power supply is damaged, it must be replaced by the manufacturer or other maintenance department or similar professional staff in order to avoid danger. The supplied water filter is only suitable for machine testing. It is easy to operate with an intelligent LED control panel. Thank you for choosing our companys fully automatic ice maker. Each foot must be screwed down and tightened. Maintaining8 In the setting state, click this button, and the parameter will increase by 1, long press this button to increase continuously. Fill our 55 mm Viski ice ball maker with a chunk of ice and watch as it transforms into a perfect orb within minutes. The normal use environment temperature is between 10( ~ 38(, and the water temperature is between 5( ~ 30(High temperature will seriously reduce ice production.The ice maker should not be installed environment without a drainage system, and strictly forbidden to put it alongside temperature equipment (such as refrigerators and ovens).The air-cooled ice maker relies on air circulation to dissipate heat. 2. When the water plate close, Ice full of storage icon lights up, Ice full of storage icon goes out when water plate opens. De-icing ( cycle work, up to 4 minutes ). Ice Thickness Control Compatible with Manitowoc Indigo Series Ice Machine . In the status of time schedule setting, press the button to reduce 1 minutes, continuously. If the ice machine is powered on the ice machine produced by our company is fully automatic and does not require manual operation, so some models do not have a power switch. Therefore, we strongly suggests that after the customer receive our machine, place the machine in the right position for a day, so that the lubricating oil can flow back to the compressor, then install and use the machine. There is nothing in the instructions about peeling it off, and it covers the entire unit. General Precautions13 Your water valve works hand in hand with your ice maker to supply water to your ice maker. More Efficient: VEVOR ice maker provides you [Faster] World"s top brands 950W SECOP compressor for rapid ice making, 14*13 ice tray for 182 clear cubes one cycle in 8-15 minutes, and up to 550lbs of ice in 24 hours. The parameters should not be adjusted too large, generally within 12-19, which can solve most situations. The heavy-duty rail slides can be installed on the side of the cabinet or machine parts. It also features an automatic cleaning function to keep your ice machine clean and bacteria-free. Have an ice day with our ice maker! VEVOR 110V Commercial Ice Maker 120-130LBS/24H with 33LBS Bin, Full Heavy Duty Stainless Steel Construction, Automatic Operation, Clear Cube for Home Bar, Include Water Filter, Scoop, Connection Hose View on Amazon SCORE 8.0 AI Score The SfCutters Reviews AI Score rating method was established by our skilled group of professionals. after decomposing the pump, use toothbrush to remove scale, and then return to normal. icon lights up and Fault icon flashes. Comment * document.getElementById("comment").setAttribute("id","af7679171c9aa663ea990870dfd0ac53");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Please use an independent water source for the ice maker, and check it regularly to prevent low water pressure, fluctuations or clogging of the filter. Display time is ice freezing time. VEVOR's commercial ice maker is an indispensable machine to meet your needs for everyday ice use. Place the ice maker on a level Make sure that there is at least 5 inches of space between the back and sides of your ice maker and the wall. 3. Press once, the screen number is -1, ice making time is -1 minutes. The shell of the ice maker has condensed water, Use manuals file type: PDF. When the thickness of the test is reached, the program will turn to the de-icing step. The fin of the condenser is very sharp, pls be careful during clean. Screw the foot to the bottom of the ice maker. The maximum reservation time is 12 hrs. Adjust the height of the feet to make the ice maker level. Adjust the height of the foot to make the ice machine level. In the power-on state, click this button to automatically turn on and enter the flushing running state. It causes thecompressor to lack of oil, then the compressor may be burn down in a short time. This appliance is suitable for the catering industry, such as kitchen areas in shops, offices or other workplaces; farms, hotels, motor hotels and residential environments, family hotel environments, catering, and similar non-retail applications. After a delay of 3 seconds, the program will be automatically saved and transferred to the normal working display. 3. Press the button ID, and the position on the screen that indicates temperature will show 00 sparklingly. LCD Panel Functions Operation12 It takes up an entire countertop but I think it hurts me especially because my kitchen is tiny. Installation and Placement of Machine Feet Screw the foot to the bottom of the ice maker. 1. shipping from them direct was terrible. The outer packing of the machine is intact. It is necessary to ensure that sockets are equipped with grounding wires and are grounded safely. [Status]forced deicing button. With the two water inlet modes, it can work with tap water and a bottled water supply. The ice thickness Level has been adjusted, and the effect of the adjustment can be observed after the de-icing is completed. I used it for 3month,water stopped running out,why no water,what problem? Products with electrical plugs are designed for use in the US. Pump--can directly observe whether there is water flowing from the evaporator up, if there is no pump failure, Refrigeration--after 10 minutes of ice making, the water in the sink will be significantly cooler, and you can feel the water temperature directly by touching the evaporator or running water. pull out the plug. It causes thecompressor to lack of oil, then the compressor may be burn down in a short time. The normal using ambient temperature is between 10-38 degree centigrade, and the water temperature is between 5-30 degree centigrade. Condenser sensor icon lights up, temperature displays EE. Reviewed in the United States on February 18, 2023, Reviewed in the United States on February 22, 2023. Electrical control system has more than 36V voltage, do not open and touch at will in use. Air-cooled ice machine relies on air circulation to dissipate heat, so it is necessary to reserve a certain space (5 inch for reference )before and after to facilitate heat dissipation. The ice maker is not suitable for outdoor use. Displaying scheduled time counts down. Ice freezing: Rreezing, Comp. At this time, the power needs to be cut off, and the water pump is taken out for disassembly and cleaning. Its December 19, 2022 and I'm still waiting for my money to be refund there is no way to contact the seller I need my money back please and thank you I want to buy a bigger one, Reviewed in Canada on September 4, 2020, Learn more how customers reviews work on Amazon, Commercial Refrigerators & Refrigeration Equipment. Vevor 110-120LBS/24H 110V Commercial Ice Maker Ice Cream - Use Manual - Use Guide PDF. When transportation and mobile location, the ice machine tilt shall not exceed 45 degrees. III. Please perform maintenance and maintenance according to the requirements of this manual in order to improve the reliability and service life of the ice maker, and avoid the increase in the energy consumption coefficient of ice production while maintaining hygiene. 1. In the shutdown state, click this button to turn on the ice maker. When the wastewater is gathered to a certain height, the pump will be automatically started to drain water. When transporting and moving the position, the tilt of the ice machine must not exceed 45 degrees. The electrical control system voltage is greater than 36V, and non-professionals are not allowed to open and touch casually. Is there recommended clearance? When it leaks for a long time, the water source is normal, otherwise, it means there is no water. Q: It is strictly forbidden to plug in and out when hands are wet. B. The filter element should be checked regularly. It looks like WhatsApp is not installed on your phone. The machine installation failure must be replaced and repaired by the manufacturer or professionals. Use a flashlight to check the cleaning effect.0verwintering maintenance: In addition to turning off the water source and power supply, the residual water in the ice maker sink, water inlet pipe, and drain line must also be drained.The water core of the water filter must be regularly replacedThe fin of the condenser is very sharp, pls be careful during clean.Make sure cut off the water and plug off, during cleaning and maintenanceif(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'manuals_plus-mobile-leaderboard-2','ezslot_15',708,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-mobile-leaderboard-2-0');Application of drain pumpWhen the drain pipe of the ice maker is lower than the sewer or too far away, the drain pump can be used to connect. Are all of the compartments lockable; or just the top? The freezer section is contained within two of the doors. Screw the feet of the ice machine to the baseplate. When the ice maker is at different ambient temperatures or in different seasons, the ice thickness during ice making will vary. Do not use excessive water pressure, do not directly flush the water pump and above the ice tray to prevent the circuit from being drenched.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'manuals_plus-narrow-sky-1','ezslot_16',707,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-narrow-sky-1-0');Maintenance of air-cooled ice machine condenser: clean the aircooled condenser once every three months. Foot Installation & Placement 1. The model and number of the ice maker there is a model nameplate on the front panel of the machine, and a model and number label on the back.Fault Code View FullscreenRelated PostsPOLYCOOL Ice Maker User ManualIce MakerVEVOR BY-300 Ice Crusher User ManualBY-300 Ice Crusher User Manual Operation instructions Check whether the power voltage conforms to that on the designationVEVOR ZBJ40KGSYP70 88 lb. Press the button goes to manual clean, in the status of ice freezing. Filter element should be checked regularly. . Usually, users only need to do some simple operations. It is necessary to avoid direct sunlight in order to avoid affecting the heat dissipation of the machine. In order to improve the reliability and service life of the ice machine, and to avoid the increase of the energy consumption of the ice output, the maintenance should be carried out according to the requirements of this manual. Do not hit the door. In order to protect your legitimate rights and interests, please pay attention to the following things when receiving and checking the machine: In the process of transportation, due to improper stacking or handling, the lubricating Oi1 in the compressor will flow into the refrigeration pipeline. 2. In order to protect your legal rights, please pay attention to the following when receiving and inspecting the goods:if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-1','ezslot_2',115,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-1-0');Whether the outer packaging of the machine is in good condition;Whether the model of the machine matches the one you bought;Whether the appearance of the machine is intact;Whether the accessory parts of the machine are complete;Whether the internal components of the machine are in good condition.During the logistic process, impertinent stack or delivery may cause lubricating oil flows into the refrigerant tube from the compressor. In the ice-making pre-cooling state, click this button to enter the ice-making operation.